???jsp.display-item.identifier??? https://repositorio.unipampa.edu.br/jspui/handle/riu/1723
Tipo: Trabalho de Conclusão de Curso
metadata.dc.title: Obtenção da resistência não drenada e coeficiente de adensamento horizontal através de ensaios de cptu e palheta
Obtaining undrained shear strength and horizontal coefficient of consolidation through cptu tests and vane test
Autor(es): Oliveira, Fernanda Raphaela Gomes de
Primeiro Orientador: Klamt, Rodrigo André
Resumo: Estuda-se neste trabalho a aplicação do método apresentado por Mantaras et al., (2014) para o cálculo da resistência ao cisalhamento não drenado (Su), com a intenção de comparar os valores encontrados através desta correlação geotécnica com valores oriundos de ensaios de palheta realizados nos bairros da Barra da Tijuca e Recreio dos Bandeirantes, RJ. Em paralelo, são apresentados dos valores do coeficiente de adensamento horizontal, estimados com base no método proposto por Teh e Houlsby (1991). Para ambas as correlações foram utilizados os resultados das curvas de dissipação do excesso de poropressão do ensaio de CPTU. Foram estudados 18 diferentes depósitos de argila mole, onde realizou-se os ensaios de Palheta e CPTU. A análise dos resultados mostrou a existência de uma boa correlação entre os valores de Su obtidos com o método proposto por Mantaras et al. (2014) e os valores de Su obtidos com o ensaio de palheta, podendo esta correlação ser recomenda para utilização em pré-projetos geotécnicos. Já os valores de Ch apresentaram valores típicos de argilas moles. Por fim, o trabalho apresenta uma colaboração ao entendimento da importância da aplicação de correlações geotécnicas para um conhecimento prévio do comportamento geotécnico dos solos.
Abstract: The study in this paper is about the application of the method presented by Mantaras et al., (2014) for calculating the resistance undrained shear (Su) with the intention of comparing the values found through this geotechnical correlation values derived from vane tests made in the neighborhoods of Barra da Tijuca and Recreio, RJ. In parallel, they present the values of horizontal coefficient of consolidation, estimated based on the method proposed by Teh and Houlsby (1991). For both correlations were used the results of dissipation of excess pore-water pressure curves of CPTU tests. Eighteen different kind of deposits of soft clay were studied, where were made the Vane and CPTU tests. The results showed that there was a good correlation between the Su values obtained with the method proposed by Mantaras et al. (2014) and Su values obtained with the Vane test, this correlation can be recommended for use in pregeotechnical projects. However Ch values showed typical values of soft clay. Finally, the paper presents a collaboration to understand the importance of applying geotechnical correlations for prior knowledge of the geotechnical behavior of soils.
metadata.dc.subject: Civil engineering
Geotechnics
Clayey soil
Resistance
Shearing
metadata.dc.publisher: Universidade Federal do Pampa
Tipo de acesso: Attribution-NonCommercial-NoDerivs 3.0 Brazil
Licença: http://creativecommons.org/licenses/by-nc-nd/3.0/br/
metadata.dc.identifier.uri: http://dspace.unipampa.edu.br/jspui/handle/riu/1718
metadata.dc.date.issued: 3-Dec-2015
???org.dspace.app.webui.jsptag.ItemTag.appears???Engenharia Civil

???org.dspace.app.webui.jsptag.ItemTag.files???
???org.dspace.app.webui.jsptag.ItemTag.file??? ???org.dspace.app.webui.jsptag.ItemTag.description??? ???org.dspace.app.webui.jsptag.ItemTag.filesize??????org.dspace.app.webui.jsptag.ItemTag.fileformat??? 
Obtenção da resistência não drenada e coeficiente de adensamento horizontal através de ensaios de cptu e palheta.pdf2.27 MBAdobe PDF???org.dspace.app.webui.jsptag.ItemTag.view???


???jsp.display-item.text3??? ???jsp.display-item.license??? Creative Commons