???jsp.display-item.identifier??? https://repositorio.unipampa.edu.br/jspui/handle/riu/5492
Tipo: Dissertação
metadata.dc.title: Desenvolvimento e validação de metodologia analítica para determinação de cloridrato de tirofibana e impurezas de síntese e estudo preliminar da estabilidade
metadata.dc.title.alternative: Development and validation of analytical methodology for determination of tirofiban hydrochloride and impurities of synthesis and preliminary study of stability
Autor(es): Feijó, Adriane Lettnin Roll
Primeiro Orientador: Malesuik, Marcelo Donadel
Resumo: A tirofibana é um fármaco inibidor molecular não peptídico derivado da tirosina que inibe a agregação plaquetária no final da cascata de coagulação, especificamente como antagonista dos receptores da glicoproteína (GP) IIb/IIIa, sendo o inibidor desta GP mais utilizado mundialmente deste a aprovação de sua nova dosagem pela FDA, em 2013, sob nome comercial de Agrastat®. A ANVISA e guias internacionais determinam que os medicamentos comercializados devem garantir a qualidade do produto e a segurança do consumidor. Neste contexto, torna-se imprescindível o desenvolvimento e validação de métodos que permitam a avaliação desde a matéria-prima até a forma farmacêutica, contemplando o estudo da estabilidade do fármaco nas formulações, a análise de produtos de degradação, identificação e determinação dos níveis de impurezas e padronização dos procedimentos de produção. Há poucos relatos na literatura sobre a determinação quantitativa da tirofibana e sobre degradação em condições forçadas. Além disso, a literatura não traz registro de desenvolvimento e validação de método indicativo da estabilidade, determinação de impurezas de síntese e produtos de degradação. Perante o exposto, este estudo objetivou o desenvolvimento e validação de método indicativo da estabilidade para determinação da tirofibana na presença de duas impurezas de síntese (impureza A e impureza C), bem como realizar estudo preliminar de estabilidade e determinar a cinética de degradação relacionando com os principais fatores de degradação. O desenvolvimento e validação do método foi realizado em concordância com os principais guias oficiais. Utilizou-se a cromatografia líquida de alta eficiência (CLAE) acoplada a detector de arranjo de fotodiodo (DAD), em 226 nm, empregando-se coluna C18 (4,6 x 250 mm, 5μm), em temperatura ambiente, com fase móvel eluída em modo gradiente, constituída de mistura de trietilamina 0,1% acidificada a pH 5,5 com ácido fosfórico e acetonitrila, em fluxo de 1 mL.min-1 e volume de injeção de 20 μL. O método apresentou linearidade, precisão, exatidão e robustez satisfatórios, além de baixos limites de detecção e quantificação, que demonstram sensibilidade na determinação da tirofibana e impurezas A e C. Apresentou-se seletivo para a determinação do fármaco e impurezas analisadas, sem interferência dos produtos de degradação gerados em condições forçadas, dados que demonstram a capacidade indicativa da estabilidade do método proposto. A tirofibana mostrou-se praticamente estável às condições de estresse oxidativo (H2O2 30% por 24 horas) e térmico (75oC por 24 horas), apresentou degradação frente à luz UVA e hidrólise ácida, obedecendo à cinética de primeira ordem. Os resultados obtidos neste trabalho demonstram a importância do aprofundamento dos estudos nesta área, no intuito de garantir a qualidade dos produtos farmacêuticos comercializados.
Abstract: Tirofiban is a non-peptidic inhibitor drug derived from tyrosine that inhibits platelet aggregation at the end of the coagulation cascade, specifically as a glycoprotein (GP) IIb / IIIa receptor antagonist, the most widely used GP inhibitor being the worldwide its new dosage by the FDA in 2013, under the trade name of Agrastat®. ANVISA and international guides determine that marketed medicines must guarantee product quality and consumer safety. In this context, it is essential to develop and validate methods that allow evaluation from the raw material to the pharmaceutical form, contemplating the study of drug stability in the formulations, the analysis of degradation products, identification and determination of the levels of impurities and standardization of production procedures. There are few reports in the literature on the quantitative determination of tirofiban and on degradation under forced conditions. In addition, the literature does not show a record of development and validation of method indicative of stability, determination of impurities of synthesis and products of degradation. This study aimed the development and validation of an indicative method of stability for determination of tirofiban in the presence of two impurities (impurity A and impurity C), as well as to perform a preliminary stability study and to determine the kinetics of degradation related to the main factors of degradation. The method development and validation were carried out in agreement with the main official guides. High-performance liquid chromatography (HPLC) coupled to a photodiode array detector (DAD) at 226 nm using a C18 column (4.6 x 250 mm, 5μm) was used at room temperature with a mobile phase eluted in a gradient mode, consisting of a mixture of 0.1% triethylamine acidified to pH 5.5 with phosphoric acid and acetonitrile, in a flow rate of 1 mL.min-1 and an injection volume of 20 μL. The method presented satisfactory linearity, precision, accuracy and robustness, as well as low limits of detection and quantification, which demonstrate sensitivity in the determination of tirofiban and impurities A and C. It was selective for the determination of the drug and impurities analyzed, without interference of the degradation products generated under forced conditions, data demonstrating the capacity indicative of the stability of the proposed method. Tirofiban was practically stable under oxidative (30% H2O2 for 24 hours) and thermal (75oC for 24 hours) conditions, presenting degradation against UVA light and acid hydrolysis, following the first order kinetics. The results obtained in this work demonstrate the importance of expanding the studies in this area, in order to guarantee the quality of commercialized pharmaceutical products.
metadata.dc.subject: Agrastat
CLAE
Impurezas
Degradação
Cinética
Agrastat
HPLC
Impurities
Degradation
Kinetics
CNPQ: CNPQ::CIENCIAS DA SAUDE
Idioma: por
metadata.dc.publisher.country: Brasil
metadata.dc.publisher: Universidade Federal do Pampa
Sigla da Instituição: UNIPAMPA
Campus: Campus Uruguaiana
Curso: Mestrado Acadêmico em Ciências Farmaceuticas
metadata.dc.identifier.citation: FEIJÓ, Adriane Lettnin Roll. Desenvolvimento e validação de metodologia analítica para determinação de cloridrato de tirofibana e impurezas de síntese e estudo preliminar da estabilidade. 130 p. Dissertação (Mestrado em Ciências Farmacêuticas) - Universidade Federal do Pampa, Uruguaiana, 2018.
Tipo de acesso: Acesso Aberto
metadata.dc.identifier.uri: http://dspace.unipampa.edu.br:8080/jspui/handle/riu/5492
metadata.dc.date.issued: 2018
???org.dspace.app.webui.jsptag.ItemTag.appears???Mestrado em Ciências Farmacêuticas

???org.dspace.app.webui.jsptag.ItemTag.files???
???org.dspace.app.webui.jsptag.ItemTag.file??? ???org.dspace.app.webui.jsptag.ItemTag.description??? ???org.dspace.app.webui.jsptag.ItemTag.filesize??????org.dspace.app.webui.jsptag.ItemTag.fileformat??? 
ADRIANE LETTNIN ROLL FEIJO até OUT 2021.pdf2.22 MBAdobe PDF???org.dspace.app.webui.jsptag.ItemTag.view???


???jsp.display-item.copyright???